Why India’s power transition depends on how well we cool it

  • Articles
  • Nov 27,26
As India’s power demand pushes transformers towards their thermal limits, Kartik Daftari is the Managing Director & CEO at Hi-Tech Radiators Pvt Ltd, explores how better cooling, smarter monitoring and retrofits can unlock capacity and extend asset life.
Why India’s power transition depends on how well we cool it

Every summer, India's unprecedented growth in power demand almost pushes the electricity grid to the edge. On May 21, the country recorded a fourth record in four days, as demand hit a peak of 270.82 GW. In the same week, electricity department workers in Uttar Pradesh were seen using pedestal fans and water sprayers to cool down a transformer.

While the visuals evoked laughter on social media, the reality is that those workers understood something that our planners tend to overlook. Their act of using pedestal fans, what many called 'jugaad', underlined the core fact that a transformer is as good as the heat it can get rid of.

A grid that is only turning hotter

India's booming power consumption is only aggravating the challenge. Room air conditioners, being used commonly in most urban households, are estimated to contribute 60-70 GW to the peak demand. Now add the growing use of solar panels, which send their heaviest flows through substations in the middle of the day, when temperatures are at their intraday peaks. Another spurt comes through the rapid deployment of EV chargers, adding sharp loads onto neighbourhood transformers that were sized for ceiling fans.

Also, transformers are set to feel the pinch of AI, as data centres are expected to add 26.3 GW of load by 2031-32, by when the all-India peak is estimated to hit 388 GW.

The surging power use will land on equipment that has shown signs of crack. The countrywide failure rate of distribution transformers stands at 10 per cent, or about 1.3 million, according to a government committee. This gets worse in some northern states, where the rate is above 20 per cent.

Bad quality, poor repairs and moisture cause many breakdowns, but overloading is on the list too, and heat is what turns overloading into failure.

Heat is the real rating

A transformer's weakest link is its insulation, or the special paper wrapping the copper coils in the windings. Excessive heat makes the paper brittle, which leads to the insulation failing and transformer stop working. According to IEC 60076-7, the international guide on how transformers are to be loaded, the paper ages normally when the hot-spot temperature is 98 degrees Celsius.

However, the aging doubles when the hot-spot temperature rises by every 6 degrees. This means that if the peak Indian summer raises it by 12 degrees, then the insulation paper would age four-times its normal pace, thereby alarmingly shortening the life of the transformer.

On the flip side, the opportunity exists to prolong the life of transformers by shedding heat faster. The industry is already pricing this, as a transformer equipped with one stage of cooling fans gets rated a third higher as compared to the regular ones.

What also matters is how the cooling system is designed. A 2026 study published in Electric Power Systems Research, which evaluated seven radiator configurations on a 20/28 MVA transformer, found that shorter radiators with higher fin density can improve heat dissipation by 27.5 per cent, while reducing the cost per kW of cooling by 34 per cent compared to the baseline. Other research points to the benefits of greater spacing between radiator tubes, which can improve heat transfer and thermal performance. These findings suggest that there is no one-size-fits-all radiator design. 

The right configuration must be determined by the space available, installation conditions and the cooling requirements of the transformer, with the aim of improving heat dissipation and extending equipment life.

Radiator design also has a significant cost implication, accounting for approximately 40 per cent of a transformer's mechanical component cost, as cited in the 2026 study. Upgrading existing radiators, adding fans where feasible and using sensors to identify units under thermal stress can help utilities improve cooling and unlock capacity from assets they already own.

This becomes particularly important when transformer lead times in India can exceed a year. Utilities cannot rely on new procurement alone to meet rising demand. Improving the cooling systems of existing transformers offers a faster and more cost-effective way to enhance their performance and extend their operational life.

What needs to change

While procuring transformers, utilities should look beyond nameplate rating and price. The single most important criteria should be to ascertain how the transformers would behave at the peak of Indian summer, when the load is maximum.

What also needs a tweak is the way we track which units are running the hottest. A laudable initiative on this front is of Maharashtra's state-run MSEDCL, which is making use of an artificial intelligence system, on a pilot basis, to foresee transformer stress and flag potentially risky feeders. This, in my view, should be adopted as a practice by all DISCOMs ahead of the summers.

DISCOMs should also give retrofits as much importance as they assign to new capital projects. After all, improving the cooling mechanism of a stressed transformer not only extends its life, but turns out to be a faster and cheaper solution for the utility.

The sectoral leader, including Tata Power-DDL and CESC, has already demonstrated what careful asset management, including cooling, can achieve. The two DISCOMs have logged failure rates under 0.5 per cent even as the national average stands over 10 per cent.

While it's a fact that India needs to step up its transformer procurement plans in view of the surging power demand, an equally undisputed fact is that the cheapest addition to the grid is already waiting to be unlocked in the substation, provided that the cooling mechanism can be put in place effectively.

About the author

Kartik Daftari is the Managing Director & CEO at Hi-Tech Radiators Pvt Ltd, he is a dynamic and visionary leader with over 20 years of experience driving innovation and growth in the global transformer industry.


Related Stories

Electrical & Electronics
Why India’s power transition depends on how well we cool it

Why India’s power transition depends on how well we cool it

As India’s power demand pushes transformers towards their thermal limits, Kartik Daftari is the Managing Director & CEO at Hi-Tech Radiators Pvt Ltd, explores how better cooling, smarter monitorin..

Read more

Related Products

Computer And Laptop

ELECTRICAL & ELECTRONIC EQUIPMENT

SICCO Engineering Works offers a wide range of computer and laptop.

Read more

Request a Quote

Test Terminal Block Utility Plus - Jttbu Plus

ELECTRICAL & ELECTRONIC EQUIPMENT

JVS Electronics Pvt Ltd offers a wide range of test terminal block utility plus - JTTBU plus.

Read more

Request a Quote

Kusam-meco Handheld Thermal Camera Model- Km 300

ELECTRICAL & ELECTRONIC EQUIPMENT

KUSAM-MECO, the innovators of new products in the Test and Measurement field, have added a new Thermal Imager with Camera.

Read more

Request a Quote
SPECIAL OFFER
QR Code

Hi There!

Now get regular updates from IPF Magazine on WhatsApp!

Click on link below, message us with a simple hi, and SAVE our number

You will have subscribed to our Industrial News on Whatsapp! Enjoy

+91 84228 74016

Hi There!

Now get regular updates from IPF Magazine on WhatsApp!

Click on link below, message us with a simple hi, and SAVE our number

You will have subscribed to our Industrial News on Whatsapp! Enjoy

+91 84228 74016